Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Irradiation tests of critical components for remote handling in gamma radiation environment

Obara, Kenjiro; Kakudate, Satoshi; Oka, Kiyoshi; Furuya, Kazuyuki; *; Tada, Eisuke; Shibanuma, Kiyoshi; Okawa, Yoshinao; Morita, Yosuke; Yokoo, Noriko*; et al.

JAERI-Tech 94-003, 73 Pages, 1994/08

[This article is unavailable to download the full text due to various reasons.]

JAEA Reports

Research and tests of position sensitive radiation detector

Emoto, Takehiko; ; Ando, Hideki

PNC TN9410 93-186, 65 Pages, 1993/09

PNC-TN9410-93-186.pdf:2.24MB

From the viewpoint of radiation protection and radiation shielding evaluation, the needs to know the positions that are irradiated by radiation are increasing, because measuring irradiated positions is useful for detecting local streaming at working areas in nuclear facilities and evaluating beam-loss from accelerators. We have investigated and experimented the characteristics of plastic scintillating fiber(PSF), that has been recently developed one of most popular position sensitive particle detectors in high energy physics, for purpose of that we can apply them to the radiation measurements as a position sensitive radiation detector. First, we referred to the results of the committed research performed in last year and to relative works. And, to aim for improvement of efficiency of gamma-ray and for stretch of the detector, we investigated efficiency and resolution of the detectors giving priorities to (a) variation of length and bundle of PSFs hamess, and (b) variation of the irradiated positions. As the results of referring to the works and the experiments on the detectors, we got the followings, (1)The method using the difference of reaching time between the scintillation photons from both ends of PSF is hopeful as position sensitive radiation detecting, because PSF has good time resolution and the time measurements have been recently developed to be rather easy and accurate methods. (2)Position resolution is 20cm to 30cm for collimated gamma-ray of $$^{137}$$Cs. And, the detectors bundled of ten PSFs have better characteristics of both efficiency and resolution. (3)When the detector is irradiated at near one of the ends, the efficiency and resolution will be 10% to 30% worse than irradiated at middle of it.

JAEA Reports

Development of the ultrasonic testing equipment for FBR; Results of R&D

; ; ; ;

PNC TN9420 92-014, 125 Pages, 1992/11

PNC-TN9420-92-014.pdf:9.3MB

This report decribes the development of multi-array type probe for FBR steamgenerator tube. We studied integration between three kinds of probes, which were for axial flaw, for circumferential flaw and for wall thickness flaw, detecting method of accuracy locating probe and basic composition of multi-channel detector. It was comfirmed that each devices had object performance in performance test. We shall use this results to study design and manufacture of ultrasonic testing equipment for steamgenerator of FBR Monju.

3 (Records 1-3 displayed on this page)
  • 1